The EA900RT G4 10kVA-20kVA double-conversion online UPS is designed to offer users efficient and reliable power protection, ensuring stable operation for connected devices in any situation.
Product Description
The EA900RT G4 10kVA-20kVA (1:1/3:1) is a double-conversion online UPS system designed to provide efficient and reliable power protection for a power range of 10kVA to 20kVA, supporting both 1:1 and 3:1 output configurations.
Features
Rear Panel
Specification
MODEL |
EA9010RT (3:1) |
EA9015RT (3:1) |
EA9020RT (3:1) |
||||
Capacity |
10kVA/10kW |
15kVA/15kW |
20kVA/20kW |
||||
INPUT |
|||||||
Input wiring |
three-phase five-wire (3Φ+N+PE) |
||||||
Rated voltage |
380/400/415Vac |
||||||
Voltage range |
190~304Vac (linear derating between 50% and 100% load); 304~478Vac (no derating) |
||||||
Rated frequency |
50/60Hz(auto-sensing) |
||||||
Frequency range |
40~70Hz |
||||||
Power factor |
≥ 0.99 |
||||||
Bypass voltage range |
- 40%~+15% (settable) |
||||||
Total harmonic distortion (THDI) |
≤ 5% |
||||||
OUTPUT |
|||||||
Output wiring |
Single-phase (L-N) |
||||||
Rated voltage |
208 (PF=0.9)/220/230/240Vac |
||||||
Voltage regulation |
±1% |
||||||
Frequency |
Synchronized to bypass in mains mode; 50/60Hz± 0.1%Hz in battery mode |
||||||
Waveform |
Sinusoidal |
||||||
Power factor |
1 |
||||||
Total harmonic distortion (THDV) |
≤ 1% (linear load); ≤ 3% (non-linear load) |
||||||
Crest factor |
3:1 |
||||||
Overload |
105%~110% for 10min, 110%~125% for 1min, 126%~150% for 30s |
||||||
BATTERIES |
|||||||
DC voltage |
192Vdc (192~240Vdc settable) |
||||||
Number of battery |
16pcs (16~20 settable) |
||||||
Inbuilt battery (standard model) |
12V/9Ah×16 |
/ |
/ |
||||
Charging current |
Standard model: 1A; Long time model: 5A (default), 1~5A settable; 10A (optional) |
||||||
Recharge time |
Standard model: 90% capacity restored in 8 hours; Long time model: depend on the capacity of battery |
||||||
SYSTEM |
|||||||
Efficiency |
≥ 94% at 100% load, max, 95% at 60% load, ≥ 98% in ECO mode |
||||||
Transfer time |
0ms |
||||||
Protections |
Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure |
||||||
Max. number of parallel connections |
4 |
||||||
Communications |
RS232 (standard), USB/RS485/dry contacts/SNMP/battery temperature compensation (optional) |
||||||
Display |
LCD+LED |
||||||
OTHERS |
|||||||
Operating temperature |
0℃~40℃ |
||||||
Storage temperature |
-25℃~55℃ (without battery) |
||||||
Relative humidity |
0~95% (non-condensing) |
||||||
Altitude |
≤ 1000m, derating 1% for each additional 100m |
||||||
IP rating |
IP 20 |
||||||
Noise level at 1 m |
≤ 58dB |
||||||
Dimensions (W×D×H) (mm) |
440×660×176 (S) 440×650×88 (H) |
440 ×780×132 |
|||||
Packaged dimensions (W×D×H) (mm) |
554x792x418 (S) 514x696x168 (H) |
554x792x400 |
|||||
Net weight (kg) |
67 (S), 17 (H) |
25.5 |
|||||
Gross weight (kg) |
77 (S), 19 (H) |