The EA990 G5 Tower UPS is a dependable power conversion and protection device designed for medium- to large-scale power demands. Its design philosophy ensures that in the event of grid faults or power outages, user equipment and systems can continue normal operation, ensuring business continuity.
Product Description
The EA990 G5 is a high-performance transformer designed to meet power requirements ranging from 10 kVA to 30 kVA, with a 3:3 input-output transformer ratio. This transformer serves as a key component of the Tower UPS (Uninterruptible Power Supply) system, aiming to provide reliable power protection.
Features
Application
Specification
MODEL |
EA9910 |
EA9915 |
EA9920 |
EA9930 |
Capacity |
10kVA/10kW |
15kVA/15kW |
20kVA/20kW |
30kVA/30kW |
INPUT |
||||
Rated voltage |
380/400/415Vac (L-L) |
|||
Voltage range |
304~478Vac (L-L), full load 228V~304Vac (L-L), load decrease linearly according to the min phase voltage |
|||
Rated frequency |
50/60Hz (auto-sensing) |
|||
Frequency range |
40Hz~70Hz |
|||
Power factor |
>0.99 |
|||
Bypass voltage range |
Selectable,default -20%~+15% Up limited: +10%, +15%, +20%, +25%; Down limited: -10%, -15%, -20%, -30%, -40% |
|||
Bypass frequency range |
Selectable, ±1Hz, ±3Hz, ±5Hz |
|||
Input Current THDi |
<3% (full Linear Load) |
|||
Bypass overload |
<125% : Long term operation; 125%~130% : 10min; 130%~150% : 1min; 150%~400%:1s; >400% ,less than 200ms |
|||
OUTPUT |
||||
Rated voltage |
380/400/415Vac (L-L) |
|||
Voltage regulation |
±3% (full Linear Load) |
|||
Frequency |
Synchronized with utility in mains mode, 50/60Hz± 0.1% in battery mode |
|||
Waveform |
Sinusoidal |
|||
Power factor |
1 |
|||
Crest factor |
3:1 |
|||
Output Voltage THDv |
<1% (full Linear Load) <5% (full non-linear load according to IEC/EN62040-3) |
|||
Overload |
<110%, 60min; 110%~125%,10min; 125%~150%,1min; >150%,200ms. |
|||
BATTERIES |
||||
Long run model battery voltage |
±240VDC(Selectable, 32 - 40pcs) |
|||
Charger Power |
10Amax |
|||
Charger Voltage precision |
1% |
|||
SYSTEM |
||||
Efficiency |
92% Max |
|||
Transfer Time |
0ms |
|||
Max. Number of parallel connections |
2 |
|||
Protections |
Short-circiut, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure |
|||
Interface |
Standard:RS232, RS485, USB,Battery cold start Option:Programmable dry contact,SNMP,Parallel kit |
|||
Display |
LED+5 inch LCD touch screen |
|||
OTHERS |
||||
Operation Temperature |
0 ~ 40 ℃ |
|||
Storage Temperature |
-40 ~ 70 ℃ |
|||
Relative Humidity |
0 ~ 95% Non condencing |
|||
Altitude |
<1000m, Load derated 1% per 100m From 1000 ~ 2000m |
|||
IP rating |
IP20 |
|||
Noise (1 meter) |
58dB |
|||
Module Dimension (W*D*H,mm) |
350×715×1032.5 |
350×845.2×1032.5 |
||
Packaged dimensions (W*D*H,mm) |
445×833×1085 |
445×938×1085 |
||
Net Weight(kg) |
110 |
132 |
145 |
190 |
Gross weight (kg) |
121 |
143 |
156 |
203 |