The EA990 G5 is a high-performance and highly reliable power system. The incorporation of isolation transformer technology enhances its electrical safety, making it an ideal choice to meet diverse power requirements.
Product Description
The EA990 G5 is a high-performance power system designed to meet power requirements ranging from 10 kVA to 60 kVA with a 3:3 output configuration. This system boasts exceptional stability and reliability, making it suitable for various applications, including industrial, commercial, and critical facilities.
Features
Specification
MODEL | EA9910 | EA9915 | EA9920 | EA9930 | EA9940 | EA9960 | |||||||
Power rating | 10kVA/10kW | 15kVA/15kW | 20kVA/20kW | 30kVA/30kW | 40kVA/40kW | 60kVA/60kW | |||||||
INPUT | |||||||||||||
Phase | 3:3/3:1/1:1 * | ||||||||||||
Rated voltage | 220/230/240Vac (L-N) 380/400/415Vac (3Φ + N + PE) | ||||||||||||
Voltage range | 132~275Vac (L-N) 228~478Vac (3Φ + N + PE) | ||||||||||||
Rated frequency | 50/60Hz | ||||||||||||
Frequency range | 40~70 Hz | ||||||||||||
Power factor | >0.99 | ||||||||||||
Bypass voltage range | Selectable, default -20%~+15% | ||||||||||||
Up limited: +10%, +15%, +20%, +25%; Down limited: -10%, -15%, -20%, -30%, -40% | |||||||||||||
Bypass frequency range | Selectable, ±1Hz, ±3Hz, ±5Hz | ||||||||||||
Input current THDi | <1%( linear load), <3% ( nonlinear load ) | ||||||||||||
Bypass overload | 125%: long term operation; 125%~130%: 10min; 130%~150%: 1min; | ||||||||||||
150%~400%: 1s; >400%, less than 200ms | |||||||||||||
OUTPUT | |||||||||||||
Rated voltage | 220/230/240Vac (L-N) 380/400/415Vac (3Φ + N + PE) | ||||||||||||
Voltage precision | ±1% (linear load) | ||||||||||||
Frequency | Synchronized with utility in mains mode, 50/60Hz±0.1% in battery mode | ||||||||||||
Waveform | Sinusoidal | ||||||||||||
Power factor | 1 | ||||||||||||
Total harmonic distortion (THDv) | <1% (full linear load); <3% (full non-linear load according to IEC/EN62040-3) | ||||||||||||
Crest factor | 3:01 | ||||||||||||
Overload | <110%, 60min; 110%~125%,10min; 125%~150%,1min; >150%, 200ms | ||||||||||||
BATTERIES | |||||||||||||
DC voltage | Long time model: ±240VDC(selectable, 32-40pcs) | ||||||||||||
Standard model battery voltage | (10+10)x9AH | (20+20)x7AH | (20+20)x9AH | (15+15)x9Ah x 2 strings | (20+20)x9AH x2 strings | / | |||||||
Charging current | 10A max. | 15A max. | 20A max. | ||||||||||
Charger voltage precision | 1% | ||||||||||||
SYSTEM | |||||||||||||
Display | 5 inch touch screen | ||||||||||||
Efficiency | 95% max. | 96% max. | |||||||||||
Transfer time | 0ms | ||||||||||||
Interface | Standard: RS232, RS485, USB, Battery cold start | ||||||||||||
Option: Programmable dry contact, SNMP, Parallel kit | |||||||||||||
ENVIRONMENT | |||||||||||||
Operating temperature | 0℃ ~ 40℃ | ||||||||||||
Storage temperature | -40℃~70 ℃ | ||||||||||||
Relative humidity | 0 ~ 95% (non condensing) | ||||||||||||
Noise level at 1m | 58dB max. | 62dB max. | |||||||||||
Altitude | <1000m, load derated 1% per 100m from 1000 ~ 2000m | ||||||||||||
OTHERS | |||||||||||||
Dimensions(W×D×H)(mm) | 250x720x560(S)250x720x560(H) | 250x800x700(S) | 250x840x930(S) 250x840x650(H) | 250x720x560(H) | 250x790x560(H) | ||||||||
250x720x560(H) | 350x800x1280(S) | ||||||||||||
Packaged dimensions(W×D×H)(mm) | 350x800x722(S) | 350x900x862(S) | 350x950x1102(S) | 350x800x718(H) | 350x850x818(H) | ||||||||
350x800x718(H) | 350x800x718(H) | 350x980x810(H) | 450x900x1400(S) | ||||||||||
Net weight(kg) | 82(S) 31(H) | 131(S) 33(H) | 145(S) 33(H) | 215(S) 42(H) | 42(H) 300(S) | 48(H) | |||||||
Gross weight(kg) | 93(S) 40(H) | 142(S) 42(H) | 156(S) 42(H) | 227(S) 52(H) | 52(H) 310(S) | 58(H) |