The EA900 G4 6kVA–10kVA is an efficient online interactive UPS (uninterruptible power supply) system designed for single-phase input and output. This system is engineered to provide stable power protection in homes, small offices, or commercial environments.
Product Description
The EA900 G4 6kVA–10kVA is an advanced uninterruptible power supply system designed to meet single-phase power requirements. Its high-efficiency online interactive technology ensures continuous power supply to devices in the event of power fluctuations or outages, effectively safeguarding electronic equipment from the impact of power issues.
Features
User Interface
Options
Rear Panel
Specification
MODEL |
EA906 |
EA9010 |
||
Capacity |
6kVA/6000W |
10kVA/10000W |
||
INPUT |
||||
Input wiring |
Single-phase three-wire (1Φ + N + PE) |
|||
Rated voltage |
208/220/230/240Vac |
|||
Voltage range |
110~176Vac (linear derating between 50% and 100% load); 176~288Vac (no derating) |
|||
Rated frequency |
50/60Hz(auto-sensing) |
|||
Frequency range |
40~70Hz |
|||
Power factor |
≥ 0.99 |
|||
Bypass voltage range |
- 40%~+15% (settable) |
|||
Total harmonic distortion (THDi) |
≤ 5% |
|||
OUTPUT |
||||
Output wiring |
Single-phase three-wire (1Φ+N+PE) |
|||
Rated voltage |
208 (PF=0.9)/220/230/240Vac |
|||
Voltage regulation |
±1% |
|||
Frequency |
Synchronized to bypass in mains mode; 50/60Hz±0.1%Hz in battery mode |
|||
Waveform |
Sinusoidal |
|||
Power factor |
1 |
|||
Total harmonic distortion (THDv) |
≤ 1% (linear load); ≤ 4% (non-linear load) |
|||
Crest factor |
3:1 |
|||
Overload |
105%~110% for 10min, 110%~125% for 1min,126%~150% for 30s |
|||
BATTERIES |
||||
DC voltage |
192Vdc (192~240Vdc settable) |
|||
Number of battery |
16pcs (16~20 settable) |
|||
Inbuilt battery (standard model) |
12V/7Ah×16 |
12V/9Ah×16 |
||
Charging current |
Standard model: 1A; Long time model: 5A (default),1~5 A settable; 12A (optional) |
|||
Recharge time |
Standard model: 90% capacity restored in 8 hours; Long time model: depend on the capacity of battery |
|||
SYSTEM |
||||
Efficiency |
≥ 94% at 100% load, max. 95% at 60% load, ≥ 98% in ECO mode |
|||
Transfer time |
0ms |
|||
Protections |
Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure |
|||
Max. number of parallel connections |
4 |
|||
Communications |
RS232 (standard), USB/RS485/dry contacts/SNMP/battery temperature compensation (optional) |
|||
Display |
LCD+LED |
|||
OTHERS |
||||
Operating temperature |
0℃~40℃ |
|||
Storage temperature |
-25℃~55℃ (without battery) |
|||
Relative humidity |
0~95% (non-condensing) |
|||
Altitude |
≤ 1000m, derating 1% for each additional 100m |
|||
IP rating |
IP 20 |
|||
Noise level at 1 m |
≤ 55dB |
≤ 58dB |
||
Dimensions (W×D×H) (mm) |
191×465×711 (S), 191×465×350 (H) |
191×495×711 (S), 191×495×350 (H) |
||
Packaged dimensions (W×D×H) (mm) |
310×654×941 (S), 318×595×475 (H) |
310×685×941 (S), 318×617×475 (H) |
||
Net weight (kg) |
53 (S), 14.5 (H) |
62 (S), 16.5 (H) |
||
Gross weight (kg) |
61 (S), 16 (H) |
70 (S), 18 (H) |