The Outdoor UPS 500-3000VA is a backup power system designed specifically for outdoor environments, with a rated capacity ranging from 500 to 3000 volt-amperes (VA). This product is primarily intended to provide continuous power support, safeguarding critical equipment from power fluctuations, outages, or other electrical issues.
Product Description
Pure sine wave interactive outdoor UPS is specially designed for outdoor communication equipment, networking equipment, traffic control systems, and other applications in city corners, countryside, or mountainous areas. High temperature resistance, frost resistance, corrosion resistance, dust prevention, and water resistance are based. With advanced functions like a wide range of input voltage and frequency, high reliability, energy savings, environmental protection, anti-thunder, remote control, remote detection, etc., our UPS can guarantee stable power supply to communication, networking, traffic control, and other devices. It is an ideal helpmate for running these important outdoor devices.
Features
Specifications
MODEL |
500VA |
1000VA |
2000VA |
3000VA |
|
Capacity |
300W |
600W |
1200W |
1800W |
|
DISPLAY |
|||||
Panel indicator |
LED |
||||
MAINS STATES |
|||||
Applications |
PC, banking system, ATM, medical system |
||||
Input voltage range |
100/110/115/120/200/220/230/240Vac±25% |
||||
Input frequency range |
45~65Hz (over-frequency automatically transfer to inverter power) |
||||
Stable output voltage range |
174~216Vac/190~238Vac/199~250Vac /210~260Vac±10Vac for 200/220/230/240Vac 87~108Vac/96~120Vac/100~125Vac/105~130Vac±10Vac for 100/110/115/120Vac |
||||
Input P.F.(AC/DC) |
98% |
||||
Efficiency |
Mains mode ≥ 96% |
||||
Mains overload |
110% for 120s, 125% for 60s , 150% for 10s |
||||
Short circuit |
Input fuse |
||||
INVERTER STATES |
|||||
Inverter output voltage |
100/110/115/120/200/220/230/240Vac±5% (battery ≥ 11Vdc) |
||||
Output frequency |
50/60Hz±1% (auto-sensing) |
||||
Output power factor |
≥ 0.6 |
||||
Waveform distortion |
Linear load ≤ 5% |
||||
Transfer time |
≤ 10ms |
||||
Efficiency |
Inverter mode ≥ 80% |
||||
Inverter overload |
110% for 60s, 125% for 10s , 150% for 5s |
||||
No-load shut-off (option) |
Load < 5% auto shutdown in 1min |
||||
Short circuit |
the system automatically shut down |
||||
ALARM |
|||||
Mains abnormal |
1/4s, be silent in 40s |
||||
Low battery |
1/0.2s |
||||
Overload |
1/1s |
||||
BATTERIES |
|||||
DC voltage |
24Vdc |
48Vdc |
|||
Inner battery space |
2×12V 38Ah/120Ah |
4×12V 38Ah/120Ah |
4×12V 120Ah |
||
Charging current |
Max. 12A |
||||
OTHERS |
|||||
Installing |
Floor standing or wall-mounted |
||||
Surge protection |
Class C |
||||
Communications |
Dry contacts/RS232/USB/SNMP (optional) |
||||
Protection grade |
IP 55 |
||||
Environmental temperature |
0℃~50℃ |
||||
Environmental humidity |
10%~95% (no cooling) |
||||
Noise |
≤ 50dB |
||||
Weight (kg) |
17.5/36.7 |
36.7/60.7 |
60.7 |
||
Dimensions (W x D x H) (mm) |
430×245×550/470×245×900 |
470×245×900/470×460×900 |
470×460×900 |
||
Packing dimensions (W x D x H) (mm) |
500×335×636/540×330×980 |
540×330×980/550×560×950 |
550×560×950 |