This row-based modular data center is an ideal solution for small to medium-sized data centers, streamlining construction complexity and addressing challenges in small data center construction and expansion. Additionally, it boasts advantages such as rapid construction, high energy efficiency, diverse configurations, and easy maintenance.
Product Description
The MC2000 series represents a cutting-edge small and medium modular data center solution. It seamlessly integrates essential components such as power supply and distribution, UPS systems, refrigeration systems, emergency ventilation modules, cabinets, airflow management, wiring, and monitoring into one or multiple closed cabinets. In single cabinet mode, the system is factory prefabricated for easy on-site installation, eliminating the need for assembly. In multi-cabinet mode, the units can be assembled on-site, creating a row of modular data centers.
Features
1. Intelligence:
- Built-in monitoring and management system.
- 10.1-inch industrial touch screen for parameter viewing.
- Remote monitoring via the internet for efficient management.
2. Ambient Lighting:
- Intelligent LED ambient lights indicate temperature status.
- White light for operation; infrared sensor-linked for smart activation.
3. High Energy Efficiency:
- Offers hot-cold aisle containment, cold aisle containment, and natural cooling.
4. Reliability:
- Adapts to various environments with modular design.
- Fault-tolerant design enhances system reliability.
- Minimizes electromagnetic interference; passes seismic performance test.
5. Simplification:
- Standard modular structure with versatile sub-modules for immediate use.
6. Flexibility:
- Easily implements multiple solutions; allows for straightforward expansion.
Specification
Overall system parameters |
Numbers of cabinet for |
1-12 |
Max.available space |
420 U(12 cabinets,without battery pack,54 kW load) |
|
Aisle type |
Single row aisle,natural cooling /cold aisle containment /hot-cold aisle containment |
|
Power density range |
3-8kW/cabinet |
|
Battery deployment |
Battery pack,battery cabinet,battery rack |
|
Battery backup time |
15 min -240 min |
|
Installation |
Concrete ground,raised flooring |
|
Power mode |
Single-phase three-wire /three-phase five-wire |
|
System protection grade |
IP 20 (mesh door)/IP 50 (glass door) |
|
Operating temperature |
-20℃~45℃ |
|
Altitude |
Derating for above 1000m |
|
|
Natural cooling |
(N×600)×1200×2000mm(excluding casters and adjusting feet,front and rear high |
Cold aisle containment |
(N×600)×1200×2000mm(excluding casters and adjusting feet,front glass door |
|
Hot-cold aisle containment |
(N×600)×1400×2000mm(excluding casters and adjusting feet,front and rear |
|
IP rating |
IP 20(mesh door)/IP 50 (glass door) |
|
Refrigeration system |
Input power supply |
220Vac |
Refrigerating capacity |
4.5kW(4U)/8kW(10U)/15kW(12U)/30kW(21U) |
|
Air conditioner configuration |
1+0,1+1,2+0,2+1,3+0,3+1(optional) |
|
Sensible heat factor |
1 |
|
Refrigerant |
R410A |
|
Air supply method |
Supply air in front and return air in the rear |
|
Installation |
Rack-mounted |
|
Power supply |
Power input |
Single-phase three-wire /Three-phase five-wire |
UPS capacity |
3kVA/6kVA/10kVA/20kVA |
|
UPS configuration |
N,N+1 |
|
UPS rated input voltage |
220/230/240Vac single-phase,380/400/415Vac three-phase |
|
UPS input voltage range |
80~280Vac single-phase,138~485Vac three-phase |
|
UPS output power factor |
0.8/0.9 |
|
UPS rated output voltage |
220/230/240Vac single-phase,380/400/415Vac three-phase |
|
UPS overall efficiency |
92%/95% |
|
Maintenance bypass |
Support |
|
Mains power feed-out way |
4 ways IT+4 ways air conditioner and fire-fighting systems / |
|
UPS feed-out way |
4 ways IT/12 ways IT |
|
AC lightning protection |
Class B,C |
|
Monitoring system |
Monitoring system host |
Support direct access for embedded Wet |
Local interface |
10.1-inch industrial touch screen |
|
Water leak detection rope |
Standard configuration |
|
Smoke detection |
Standard configuration |
|
Temperature and humidity |
Standard configuration |
|
Automatic spring door device |
Optional configuration |
|
Door sensor |
Optional configuration |
|
Power supply and distribu- |
Standard configuration |
|
Northbound communication |
Optional configuration |
|
Protocol format |
SNMP |
|
SMS alarm |
Optional configuration |
|
Rechargeable fan |
Optional configuration |
|
Rope light in cabinet |
Standard configuration |
|
Firefighting system |
Heptafluoropropane gas |
1U rack installation,a single module can manage two cabinets (optional) |
Product Benefits
MC2000's hot-cold aisle containment maximizes cooling efficiency and energy savings.
The cold aisle solution targets device-specific cooling, suitable for areas with many cables.
Natural cooling eliminates the need for an air conditioning system, utilizing mesh doors for temperature control without additional cooling systems.